General Specifications

3051 General SPEC
  • • Reference Accuracy: ±0.075%
  • • Stability: ±0.125% of URL for 5 years
  • • Power Supply: 10.5 to 55 V dc
  • • Overpressure Limits:
  • -3051CG Ranges 2-5: 3626 psig (250 bar)
  • -3051TG:
  • - • Range 2: 1500 psi (103,4 bar)
  • - • Range 3: 1600 psi (110,3 bar)
  • - • Range 4: 6000 psi (413,7 bar)
  • • Burst Pressure:
  • -3051CG all Ranges: 10000 psig (69 MPa)
  • -3051T Ranges 1 to 4: 11000 psi (75,8 MPa)
  • -3051T Range 5: 26000 psig (179 MPa)
  • • Temperature Limits:
  • -Ambient: -40 - +85 °C ( -20 - 80 °C with LCD)
  • -Storage: -46 - +110 °C ( -20 - +80 °C with LCD)
  • -Process: -40 - 120 °C with Siliconoil Fill
  • • Humidity: 0 - 100%

Model 3051TG3 with Remote Seal

3051T+1199
  • • Range: -14.7 to 800 psi/8 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • LCD Meter
  • • Calibration Certification

  • Complete with Diaphragm Seals

  • • Fill Fluid: D.C. Silicone 200, Range: -45 to 205 °C
  • • Tube ID: 0.04-inch (1,1 mm); Tube Material: 316 SST Armored Sleeving
  • • Tube Length: 1.5 meter
  • • Standard: ANSI/ASME B16.5
  • • Process Connection Style: Threaded / Size: 1/2-14 NPT
  • • Pressure Rating: 2500 psi Maximum Working Pressure
  • • Materials; Diaphragm: 316L SST, Upper Housing:316 SST; Mounting Ring: CS
  • • Flushing Connection Ring (Lower Housing) Material: 316 SST
  • • Flushing: One 1/4 in. Flushing Connection

Model 3051L Tank Level

3051L
  • • Range: 1000 inH2O (2.5 bar)
  • • Output: 4-20 mA HART Protocol
  • • High Side; Diaphragm; Size: 3 Inch, Material: 316L SST, Extension Length: Flush Mount
  • • Mounting Flange: 3 Inch, Class 150, ANSI; Material: CS
  • • Process Fill-High Pressure Side: D.C. Silicone 200; -40 to 205 °C
  • • Low Side; 316L SST DP Diaphragm, SST Flange Adtapter, Silicone Oil Fill Fluid
  • • O-ring Material: Glass-filled TFE
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • FM Intrinsically Safe, Non-incendive
  • • LCD Meter
  • • 1/2-14 NPT Flange Adapters: 316 SST

Model 3051CG4

3051CG
  • • Range: -14.7 to 300 psi/3 psi
  • • Output: 4-20 mA HART Protocol
  • • Plated CS Coplanar Process Flange; SST Drain/Vent
  • • Isolating Diaphragm: 316L SST
  • • O-ring: Glass-filled TFE
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • FM Intrinsically Safe, Non-incendive
  • • LCD Meter
  • • 1/2-14 NPT Flange Adapters: 316 SST
  • • Calibration Certificate
  • • Material Traceability Certification per EN 10204 3.1B

Model 3051TG2

3051T
  • • Range: -14.7 to 150 psi/1.5 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • LCD Meter
  • • Calibration Certification

Model 3051TG3

3051T
  • • Range: -14.7 to 800 psi/8 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • LCD Meter
  • • Calibration Certification

Model 3051TG4

3051T
  • • Range: -14.7 to 4000psi/40 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • LCD Meter
  • • Calibration Certification

Model 3051TG4

3051T
  • • Range: -14.7 to 4000psi/40 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • ATEX Flameproof, Intrinsically Safe, Type n, Dust
  • • LCD Meter

Model 3051TG4

3051T
  • • Range: -14.7 to 4000psi/40 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • ATEX Flameproof, Dust
  • • LCD Meter
  • • Hydrostatic Testing with Certificate

Model 3051TG4

3051T
  • • Range: -14.7 to 4000psi/40 psi
  • • Output: 4-20 mA HART Protocol
  • • Process Connection: 1/2-14 NPTF
  • • Isolating Diaphragm: 316L SST
  • • Sensor Fill Fluid: Silicone Oil
  • • Housing: Covered Al.; Conduit Entry: 1/2-14 NPT
  • • Bracket for 2-in. Pipe
  • • LCD Meter
  • • Hydrostatic Testing with Certificate